Construction details library for concrete, steel and composite structures. Includes foundations, from pad footings to pile caps, mat foundations, walls and shear walls.

Construction details

© CYPE Ingenieros, S.A.

 

In English

En castellano

En català

En galego

Adaptado para Argentina

Adaptado para México

Em português

Adaptado para o Brasil

En français

In Italian

In Bulgarian

In Chinese

Construction Details: steel, concrete and composite

 
   

Intermediate interface in slurry wall through continuous angles.

One-way floor slab.

Lattice joists.

   

CCP306

   


  • Mechanically the joint consists of a simple support. Pay special attention to the bottom reinforcement since it may run short of the support depending on the model employed in the analysis of the slab - the contribution of the negative reinforcement is minimal.

  • The values given correspond to floors in buildings with a total load not exceeding 200 psf and spans not greater than 20 ft.

  • If the solution of discontinuous angles is adopted, the angles, anchors, and edge beam must be analyzed.

  • All steel elements in the connections must be adequately protected against corrosion, consequently it is essential that the top of the joint between the floor and the wall be sealed to prevent infiltrations.